21
              
            
            
              
                ORIGINAL
              
            
            
              Actualidad
            
            
              
                A C T U A L I D A D
              
            
            
              
                M É D I C A
              
            
            
              www.actual idadmedica.es
            
            
              
                ©2012.Actual.Med.Todoslosderechosreservados
              
            
            
              Médica
            
            
              
                Preservación hipotérmica del intestino
              
            
            
              
                delgado: un estudio morfológico mediante
              
            
            
              
                microscopía electrónica de barrido
              
            
            
              
                Resumen
              
            
            
              
                Introducción:
              
            
            
              El objetivo del presente estudio es analizar el efecto de soluciones cristaloides simples (solución
            
            
              salina y solución de Ringer Lactato) y una solución de preservación de órganos compleja (solución Celsior)
            
            
              sobre la la pared intestinal de ratones mediante el empleo de microscopía electrónica de barrido tras su pre-
            
            
              servación hipotérmica.
            
            
              
                Material y Métodos:
              
            
            
              Los segmentos intestinales de íleon procedentes de ratones CD1 fueron perfundidos por
            
            
              vía vascular e intraluminal con soluciones cristaloides simples como el suero salino (grupo 2) o solución de
            
            
              Ringer-Lactato (grupo 3), y con soluciones complejas como la solución Celsior (grupo 4). Los segmentos fueron
            
            
              almacenados durante 14 horas a 4º C con la misma solución empleada para su perfusión. Las diferentes mues-
            
            
              tras fueron procesadas utilizando protocolos convencionales para microscopia electrónica de barrido.
            
            
              
                Resultados:
              
            
            
              Nuestros resultados muestran que el grupo 2 se caracterizó por presentar un patrón vellositario y
            
            
              microvellositario compatible con el grupo control (grupo 1). El grupo 3 mostró lesiones focales caracterizadas
            
            
              por pérdidas epiteliales a nivel del vértice vellositario y exposición del eje conjuntivo-vascular de la vellosidad.
            
            
              Finalmente, el grupo 4 presentó un patrón vellositario desestructurado con hendiduras subepiteliales exten-
            
            
              sas, así como destrucción de células enterocíticas hasta la base.
            
            
              
                Discusión:
              
            
            
              El estudio demuestra que las soluciones cristaloides simples administradas por vía vascular e in-
            
            
              traluminal mantienen la integridad morfológica de la mucosa intestinal tras su preservación hipotérmica. La
            
            
              microscopia electrónica de barrido constituye una metodología óptima en la valoración topográfica del daño
            
            
              tisular inducido por diferentes protocolos de preservación.
            
            
              
                Abstract
              
            
            
              
                Introduction:
              
            
            
              The aim of this study is to analyze the effect of simple crystalloid solutions (saline and Ringer
            
            
              lactate solution) and an organ preservation solution (Celsior) on murine intestinal ileal mucosa by scanning
            
            
              electron microscopy after hypothermic preservation.
            
            
              
                Material and Methods
              
            
            
              : The intestinal segments of ileum from CD1 mice were intravascularly and intraluminally
            
            
              flushed with 3 different preservation solutions. The used solutions were the simple crystalloid solution normal
            
            
              saline -group 2- and Lactated Ringer (LR) -group 3-. As organ preservation solution, the solution Celsior -group
            
            
              4- was used. The segments were stored for 14 hours at 4 ° C with the same solution used for perfusion. The
            
            
              samples were processed using standard protocols for scanning electron microscopy.
            
            
              
                Results:
              
            
            
              Our results show that group 2 was characterized by villous and microvilli pattern similar to the control
            
            
              group (group 1). The group 3 showed focal lesions characterized by missing epithelium at the apex level and
            
            
              the exposure of the connective-vascular axis of the villi. Finally, group 4 presented a disrupted villous pattern
            
            
              with extensive subepithelial clefts as well as complete denuded villi.
            
            
              
                Discussion:
              
            
            
              This study shows that simple crystalloid solutions administered via vascular and intraluminal main-
            
            
              tain morphological integrity of the intestinal mucosa after hypothermic preservation. In addition, scanning
            
            
              electron microscopy is an optimal methodology to evaluate the topographical tissue damage induced by va-
            
            
              rious preservation protocols.
            
            
              María Ángeles Muñoz Miguelsanz
            
            
              1
            
            
              , Ricardo Fernández Valadés
            
            
              1
            
            
              , Eduardo Fernández Segura
            
            
              2
            
            
              
                1
              
            
            
              
                Servicio de Cirugía Pediátrica. Hospital Universitario Virgen de las Nieves, Granada
              
            
            
              
                2
              
            
            
              
                Departamento de Histología. Facultad de Medicina de la Universidad de Granada
              
            
            
              Dra Mª Ángeles Muñoz Miguelsanz
            
            
              Servicio de Cirugía Pediátrica
            
            
              Hospital Universitario Virgen de las Nieves, Granada
            
            
              e-mail: bora.munoz@gmail.com
            
            
              Tlf.: (+34) 620 315 988
            
            
              
                Palabras clave: Trasplante intes-
              
            
            
              
                tinal pediátrico; Celsior; Ringer
              
            
            
              
                Lactato; Suero salino; Microsco-
              
            
            
              
                pía electrónica de barrido.
              
            
            
              
                Keywords: Pediatric intestinal
              
            
            
              
                transplant; Celsior solution;
              
            
            
              
                Ringer Lactate; Saline Solution;
              
            
            
              
                Scanning Electron Microscopy.
              
            
            
              Hypothermic preservation of small bowel: a morphological
            
            
              scanning electron microscopy study
            
            
              
                Actual. Med.
              
            
            
              
                2012; 97 (787): 21-26
              
            
            
              
                Enviado 15-11-2012
              
            
            
              
                Revisado 14-12-2012
              
            
            
              
                Aceptado 31-12-2012